Fluke 726 Precision Multifunction Process Calibrator

The Fluke 726 Precision Multifunction Process Calibrator is designed specifically for the Process industry with broad workload coverage, calibration power and unsurpassed accuracy in mind. The 726 measures and sources almost all process parameters and can calibrate almost anything. The 726 will also interpret results without the help of a calculator and store measurement data for later analysis.



Description

Measurement Accuracy
Voltage DC
30.000 V  0.01%+ 2 mV (upper display)
20.000 V  0.01%+ 2 mV (lower display)
90.00 mV  0.01%+ 10μV
-10.00 mV to 75.00 mV  0.025 % + 1 count (via TC connector)
Current DC
24.000 mA  0.01%+ 2 mA
Resistance
0.0 to 4000.0 Ω  +/- 0.015%
Frequency
2.0 to 1000.0 CPM  0.05 % + 0.1 cpm
1.0 to 1000.0 Hz  0.05 % + 0.1 Hz
1.00 to 15.00 kHz  0.05 % + 0.01 kHz
Sensitivity  1 V peak-to-peak-minimum
Pressure
Accuracy  from 0.025% of range using any of 29 pressure modules.
 (for detailed specifications refer to pressure modules in options and accessories)
 Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
Source Accuracy
Voltage DC
100.00 mV  0.01%+10 μV
20.000 V  0.01%+2 mV
-10.00 mV to 75.00 mV  0.025 % + 1 count (via TC connector)
Current DC
24.000 mA (Source)  0.01%+ 2 μA
24.000 mA (Simulate)  0.01%+ 2 μA
Resistance
Range, Accuracy (Percent of reading + floor) and Excitation Current  5 to 400 Ω, 0.015% + 0.1 Ω, 0.1 to 0.5mA
 5 to 400 Ω, 0.015% + 0.05 Ω, 0.5 to 3mA
 400 to 1500 Ω, 0.015% + 0.5 Ω, 0.05 to 0.8 mA
 1500 to 4000 Ω, 0.015% + 0.5 Ω, 0.05 to 0.4 mA
Frequency
2.0 to 1000.0 CPM  0.05%
1.0 to 1000.0 Hz  0.05%
1.0 to 10.0 kHz  0.25%
10.0 to 15.0 kHz  0.5%
Waveform:  5 V p-p squarewave, -0.1 V offset
RTDs and Thermocouples
Measure and Source Accuracy:
Cu10  1.8 °C
NI-120  0.15 °C
PT-100 (385)  0.45 °C
PT-100 (392)  0.35 °C
PT-100 (391-JIS)  0.35 °C
PT-200 (385)  0.95 °C
PT-500 (385)  0.55 °C
PT-1000 (385)  0.35 °C
RTD Resolution:  0.01 C (0.01 F)
Cu10.01 C  0.1 C (0.1 F)
J:  0.4 °C
K:  0.5 °C
T:  0.4 °C
E:  0.4 °C
R:  1.4 °C
S:  1.4 °C
B:  1.4 °C
L:  0.45 °C
U:  0.45 °C
N:  0.6 °C
XK:  0.4 °C
BP:  1.1 °C
TC Resolution  J, K, T, E, L, N, U: 0.1 °C, 0.1 °F B, R, S: 1 °C, 1 °F
Specifications
Ramp Functions
Source functions:  Voltage, current, resistance, frequency, temperature
Ramps  Slow ramp, Fast ramp, 25% step-ramp
Loop Power Function
Voltage:  24 V
Accuracy:  10%
Maximum current:  22 mA, short circuit protected
Step Functions
Source functions:  Voltage, current, resistance, frequency, temperature
Steps  25% of range, 100% of range
Environmental Specifications
Operating Temperature
 -10 °C to +55 °C
Storage Temperature
 -20 °C to +71 °C
Operating Altitude
 3000 m
Safety Specifications
Agency Approvals
 EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992
Mechanical & General Specifications
Size
 200mm x 96mm x 47mm (7.9 in x 3.8 in x 1.9 in)
Weight
 650 g (23 oz.)
Batteries
 4 AA alkaline batteries
Battery Replacement
 Separate battery compartment, accessible without breaking calibration seall
Side port connections
 Pressure module connector, also used for remote real-time programming
Fluke 726 Precision Multifunction Process Calibrator