Fluke 360 AC Leakage Current Clamp Meter

Ideally designed for non-invasive checks of insulation condition, the Fluke 360 leakage meter allows you to perform tests without powering down the installation or disconnecting equipment – saving you time, without compromising on quality or safety.

The unique jaw design of the Fluke 360 AC Leakage Current Clamp Meter eliminates the influence of adjacent current conductors, and minimizes the effects of external magnetic fields, even at low currents. This allows you to perform accurate and reliable tests in today’s crowded electrical environments. The tough and high-quality jaw design of the Fluke 360 leakage tester guarantees high stability for long-term repeatability and durability.

Why leakage current testing?
Leakage currents can be an indicator of the effectiveness of insulation on conductors. High levels of leakage current may be present in circuits where either the insulation resistance is low, or electronic equipment with filters is used. Leakage currents can cause disruptions of the normal operation of equipment and installations. It is possible to locate the source of leakage currents by using the Fluke 360 leakage current clamp meter and taking methodical measurements throughout the installation. The big advantage of leakage current testing versus insulation testing is that the installation and equipment do not need to be powered down but can be done during normal operation.



Description

General Specifications
Method of detection
 Mean value
Display
Digital display:  3200 counts
Bar-graph display:  32 segments, LCD
Measurement Cycle
 2 times/second (Digital display), 12 times/second (Bar-graph display)
Range switching
 Auto-range
Ambient temperature and humidity
 0 °C to 50 °C, 80 % RH or less (no condensation)
Temperature coefficient
 0.05% of range/°C or less (within the ranges of 0 °C to 18 °C and 28 °C to 50 °C for measurement of 0-50 A)
Influence of external magnetic field
 0.0005% typical
Influence of conductor position
 Within accuracy
Circuit voltage
 <300 Vrms
Safety standard
 EN 61010-1, EN 61010-2-032, 300 V CAT III, Pollution Degree 2
Withstanding voltage
 3.7 kV ac
Battery type
 1 x 3 V Lithium battery (button cell) CR2032
Battery life
 Approx. 90 hours (when continuously used)
Auto power-off
 Approx. 10 minutes
Diameter of measurable conductor
 40 mm max.
Weight
 200 g
Dimension
 176 mm x 70 mm x 25 mm
Operating altitude
 2000 m
Electrical Specification
Specifications at
 23 ± 5 ºC, 80 % RH max
Accuracy
 (% readout + value of least significant digit)
3 mA
 Resolution: 0.001 mA
Accuracy: 1% + 5
Max Permissible current: 60 A rms
30 mA
 Resolution: 0.01 mA
Accuracy: 1% + 5
Max Permissible current: 60 A rms
30 A
 Resolution: 0.01 A
Accuracy: 1% + 5
Max Permissible current: 60 A rms
60 A
 Resolution: 0.1 A
Accuracy: 5% + 5
Max Permissible current: 60 A rms
Mean value detection and rms-value calibration
Accuracy specified at:  50/60 Hz