Fluke 1652C Multifunction Installation Tester

The 1652C Installation Tester builds upon the rugged reputation of the earlier 1650 Series, only it’s re-designed to meet your need for more productive test tools.

This installation tester offers the following new capabilities:

  • Fast high current loop test
  • Variable RCD current mode for customized settings
  • PASS/FAIL indication for RCD tests
  • Select voltage measurement between L-N, L-PE and N-PE
  • Zero adapter for easy test lead compensation, available as new accessory and also included with standard scope of supply
  • Extended documentation mode (UK only)


Description

Specifications
AC Voltage Measurement
Range:  500 V
Resolution:  0.1 V
Accuracy (50 – 60 Hz)  ± (0.8% + 3 digits)
Input Impedance  3.3 MΩ
Overload Protection  660 Vrms
Continuity Testing
Range (autoranging):  20 Ω, 200 Ω, 2000 Ω
Resolution:  0.01 Ω, 0.1 Ω, 1 Ω
Test Current:  > 200 mA
Open Circuit Voltage:  > 4 V
Accuracy:  ± (1.5%+3 digits)
Insulation Resistance Measurement
Test Voltage:  250 – 500 – 1000 V
Test Voltage:  250 V
Test Current:  1 mA @ 250 kΩ
Range/Resolution:  20 MΩ/0.01 MΩ
Range/Resolution:  200 MΩ/0.1 MΩ
Accuracy:  ± (1.5% + 3 digits)
Test Voltage:  500 V
Test Current:  1 mA @ 500 kΩ
Range/Resolution:  20 MΩ/0.01 MΩ
Range/Resolution:  200 MΩ/0.1 MΩ
Accuracy:  ± (1.5% + 3 digits)
Range/Resolution:  500 MΩ/1 MΩ
Accuracy:  10%
Test Voltage:  1000 V
Test Current:  1 mA @ 1 MΩ
Range/Resolution:  20 MΩ/0.01 MΩ
Range/Resolution:  200 MΩ/0.1 MΩ
Accuracy:  ± (1.5% + 3 digits)
Range/Resolution:  500 MΩ/1 MΩ
Accuracy:  10%
Auto Discharge:  Discharge time constant, 0.5 second for
C = 1 µF or less
Live Circuit Detection:  Inhibits test if terminal voltage > 30 V prior to initiation of test
Maximum Capacitive Load:  Operable with the 5 µF load
Loop Impedance Measurement (High Current Mode and Non-Trip Mode)
Range:  100 – 500 VAC (50/60 Hz)
Input connection:  Soft Key selection
Loop impedance:  Phase to earth
Line impedance:  Phase to neutral
Limit on consecutive tests:  Automatic thermal shutdown after 50 consecutive tests at 10 second intervals (typical)
Max. Test Current. High Current and Non-Trip Modes:
Maximum Test Current @ 400 V  20 A sinusoidal for 10 ms
Maximum Test Current @ 230 V  12 A sinusoidal for 10 ms
Range/Resolution:  20 Ω/0.01 Ω
Range/Resolution:  200 Ω/0.1 Ω
Range/Resolution:  2000 Ω/1 Ω
Accuracy (no Trip mode):  ± (3% + 6 digits)
Accuracy (Hi Current mode):  ± (2% + 4 digits)
PFC, PSC Test
Computation:  PFC or PSC determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance
Range:  0 – 25 kA
Resolution (Ik < 1000 A):  1 A
Resolution (Ik >= 1000 A):  0.1 kA
Accuracy:  Determined by accuracy of loop resistance and mains voltage measurements.
RCD Testing ¹
G  General, no delay
S  Time delay
A  Responds to pulsed signal
AC  Responds to AC
Tripping Time Test (ΔT)
Trip Time Accuracy  ±(1% Reading + 1 digit)
Multiplier:  x ½
Current Settings:  10, 30, 100, 300, 500, 1000 mA
Current Accuracy:  +0% – 10%
RCD Type ¹:  G
Measurement Range:  310 ms (Europe), 2000 ms (UK)
RCD Type ¹:  S
Measurement Range:  510 ms (Europe), 2000 ms (UK)
Multiplier  x 1
Current Settings:  10, 30, 100, 300, 500, 1000 mA
Current Accuracy:  +10% – 0%
RCD Type ¹:  G
Measurement Range:  310 ms
RCD Type ¹:  S
Measurement Range:  510 ms
Multiplier:  x 5
Current Settings:  10, 30 mA
Current Accuracy:  ±10%
RCD Type ¹:  G
Measurement Range:  50 ms
RCD Type ¹:  S
Measurement Range:  160 ms
Tripping Current (ramp)
Current Range:  50% – 110% of RCD’s rated current
Step Size:  10% of IΔN
Dwell time (Type G): ¹  300 ms / step
Dwell time (Type S): ¹  500 ms / step
Trip Current Measurement Accuracy:  ±5%
Phase Sequence Indication
Icon:  Icon Phase Sequence indicator is active
Display of Phase Sequence:
 Displays ‘1-2-3’ in digital display field for correct sequence.
 Displays ‘3-2-1’ for incorrect phase.
 Dashes in place of a number indicate a valid determination could not be made.
Environmental Specifications
Operating Temperature
 -10 °C to 40 °C
Humidity (Without Condensation)
10 to 30 °C:  95%
30 to 40 °C:  75%
Safety Specifications
Safety Rating
 EN 61010-I CAT III 500V, CAT IV 300V
Mechanical & General Specifications
Size
(L x W x H):  10 x 25 x 12.5 cm
Weight
 1.3 kg
Batteries
Type AA:  6
Warranty
 3 years
Battery type
 Alkaline supplied, usable with 1.2V NiCD or NiMH rechargeable batteries
Fluke 1652C Multifunction Installation Tester