Fluke 1650 Series Multifunction Installation Testers

The 1650B Series builds on the rugged reputation of the earlier 1650 Series, but re-designed to meet your need for a more productive test tool.

This series of multifunction testers contains the following new features:

  • Fast high current loop test
  • Variable RCD current mode for customized settings
  • PASS/FAIL indication for RCD tests
  • Select voltage measurement between L-N, L-PE and N-PE
  • Zero adapter for easy test lead compensation, available as new accessory and also included with standard scope of supply
  • Loop & Line Resistance – mΩ resolution (High Current) (Fluke 1654B)
  • Test smooth dc sensitive RCDs (Type B) (Fluke 1654B)
  • Extended Memory (Fluke 1654B)
  • Extended documentation mode (UK only) (Fluke 1654B)


Description

Specifications
AC Voltage Measurement
Range:  500 V
Resolution:  0.1 V
Accuracy (50 – 60 Hz)  ± (0.8% + 3 digits)
Input Impedance  3.3 MΩ
Overload Protection  660 Vrms
Continuity Testing
Range (autoranging):  20 Ω, 200 Ω, 2000 Ω
Resolution:  0.01 Ω, 0.1 Ω, 1 Ω
Test Current:  > 200 mA
Open Circuit Voltage:  > 4 V
Accuracy:  ± (1.5%+3 digits)
Insulation Resistance Measurement
Test Voltage:
Fluke 1652C:  250 – 500 – 1000 V
Fluke 1653B + 1654B:  50 – 100 – 250 – 500 – 1000 V
Test Voltage:  50 V
Test Current:  1 mA @ 50 kΩ
Insulation Range:  10 kΩ – 50 мΩ
Resolution:  0.01 мΩ
Accuracy:  ± (3% + 3 digits)
Test Voltage:  100 V
Test Current:  1 mA @ 100 kΩ
Range/Resolution:  20 MΩ/0.01 MΩ
Range/Resolution:  100 MΩ/0.1 MΩ
Accuracy:  ± (3% + 3 digits)
Test Voltage:  250 V
Test Current:  1 mA @ 250 kΩ
Range/Resolution:  20 MΩ/0.01 MΩ
Range/Resolution:  200 MΩ/0.1 MΩ
Accuracy:  ± (1.5% + 3 digits)
Test Voltage:  500 V
Test Current:  1 mA @ 500 kΩ
Range/Resolution:  20 MΩ/0.01 MΩ
Range/Resolution:  200 MΩ/0.1 MΩ
Accuracy:  ± (1.5% + 3 digits)
Range/Resolution:  500 MΩ/1 MΩ
Accuracy:  10%
Test Voltage:  1000 V
Test Current:  1 mA @ 1 MΩ
Range/Resolution:  20 MΩ/0.01 MΩ
Range/Resolution:  200 MΩ/0.1 MΩ
Accuracy:  ± (1.5% + 3 digits)
Range/Resolution:  500 MΩ/1 MΩ
Accuracy:  10%
Auto Discharge:  Discharge time constant, 0.5 second for C = 1 µF or less
Live Circuit Detection:  Inhibits test if terminal voltage > 30 V prior to initiation of test
Maximum Capacitive Load:  Operable with the 5 µF load
Loop Impedance Measurement (High Current Mode and Non-Trip Mode)
Range:  100 – 500 VAC (50/60 Hz)
Input connection:  Soft Key selection
Loop impedance:  Phase to earth
Line impedance:  Phase to neutral
Limit on consecutive tests:  Automatic thermal shutdown after 50 consecutive tests at 10 second intervals (typical)
Max. Test Current High Current Mode:
Non-Trip Mode:
Range/Resolution (High Current):  20 Ω/0.001Ω (1mΩ) (Fluke 1654B)
Range/Resolution:  20 Ω/0.01 Ω
Range/Resolution:  200 Ω/0.1 Ω
Range/Resolution:  2000 Ω/1 Ω
Accuracy (no Trip mode):  ± (3% + 6 digits)
Accuracy (Hi Current mode):  ± (2% + 4 digits)
Accuracy (Hi Current mode 1mΩ):  ± (2% + 15 digits) (Fluke 1654B)
PFC, PSC Test
Computation:  PFC or PSC determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance
Range:  0 – 25 kA
Resolution (Ik< 1000 A):  1 A
Resolution (Ik>= 1000 A):  0.1 kA
Accuracy:  Determined by accuracy of loop resistance and mains voltage measurements.
RCD Testing ¹
Fluke 1654B:  A, AC, B, B+, F, G/R, S
Fluke 1652C:  A, AC, F, G/R, S
Fluke 1653B:  A, AC, F, G/R, S
Environmental Specifications
Operating Temperature
 -10 °C to 40 °C
Humidity (Without Condensation)
10 to 30 °C:  95%
30 to 40 °C:  75%
Safety Specifications
Safety Rating
 EN 61010-I CAT III 500V, CAT IV 300V
Mechanical & General Specifications
Size
(L x W x H):  10 x 25 x 12.5 cm
Weight
 1.3 kg
Batteries
Type AA:  6
Warranty
 3 years
Battery type
 Alkaline supplied, usable with 1.2V NiCD or NiMH rechargeable batteries
Fluke 1650 Series Multifunction Installation Testers